Rooftop unit features:Capacity: 10~350KWEfficiency: 2.7~3.3 cop.Warranty: Compressor- 3 years limited. other parts-1 year limited.StructurePanels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance toatmospheric agents.Direct expansion coils with condensate

Featured Products

Natural Gas Heating Coil Rooftop Air Handling Unit



Natural Gas Heating Coil Rooftop Air Handling Unit

Rooftop unit features:
Capacity: 10~350KW
Efficiency: 2.7~3.3 cop.
Warranty: Compressor- 3 years limited. other parts-1 year limited.

Structure
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance toatmospheric agents.
Direct expansion coils with condensate drain tray.


Hermetic compressor
High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater,mounted on rubber vibration dampers
Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise


Centrifugal fan
Forward curve centrifugal fans for air treatment section and axial fans for condensation section. Front, side and underside air discharge of the treatment unit. High external pressure, long air supply distance

Electric panel
Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.

Easy operation line controller
Cooling/Heating/Auto. Error indication. Timing on/off.

Optional
Economizer with fresh, return air dampers and fresh air hood.
Free cooling function for low ambient temperature.
Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices.
T3 (Tropical climate).
Condenser coil guard.
Roof curb.
Metal / aluminum filter.
Air pressure switch for indoor fan.
High static condenser fan option with sealed + drain.condensing section.
Optional water heating coil.
Metal or plastic mesh on condenser coil.
Optional supply / return air configurations.
Upgraded evaporator fan motor drives.
G4 filter, plate and bag filter.


Natural Gas Heating Coil Rooftop Air Handling Unit
Natural Gas Heating Coil Rooftop Air Handling Unit


Technical Data
   GT-WKR Series-Roof Top AH Specifiaction 1
Model   GT-WKR-10151820253035
SpecificationCooling capacity 1*kW10.515.018.521.026.329.835.0
Heating capacity 2*kW11.515.919.522.127.632.637.1
Supply air 3*m3/h1800240029003500450050005800
Static pressure 3*Pa100150150180200250250
Noise 4*dB(A)60606262656568
Power3N-380V-60Hz
Total capacity3.95.747.08.279.9611.014.15
ColorWhite
ooling systemCompressorTypeEfficient scroll closed 
Quantity1111112
Supply air fanTypeLow noise centrifugal type
CapacitykW0.370.550.750.751.11.52.2
EvaporatorTypeInner grooved copper tube and aluminum fin
Fin type 5*Slotted fin hydrophilic aluminum fin
CondenserTypeInner grooved copper tube and aluminum fin
Fin type 5*Rippled hydrophilic aluminum fin
Condenser fanTypeLow noise axial type
Quantity1111112
RefrigerantRefrigerantR22/R407C
Refrigerant controlExternal balance type thermal expansion valve
Air filterInitially effect plate filter
DimensionsLmm1400140016001600185018502200
Wmm1050105012001200140014001800
Hmm1050105010501050120012001520
Weightkg200230260300550600850
  1.   Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
  2.   Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
  3.   The air volume and static pressure`s specification in the table is standard, and can be designable.
  4.  Noise data is measured in the front of the units when cooling under the standard air volume.
  5.  Fin type and material can be designable. 
   GT-WKR Series-Roof Top AH Specifiaction 1
Model   GT-WKR-4050607090110120
SpecificationCooling capacity 1*kW42.052.861.270.287.5105.1122.5
Heating capacity  2*kW44.155.462.573.892.8112.0130.0
Supply air 3*m3/h700086001000012000145001700020000
Static pressure 3*Pa300300300350350400400
Noise 4*dB(A)68696970717272
Power3N-380V-60Hz
Total capacity17.2420.7223.029.7639.144.6651.58
ColorWhite
ooling systemCompressorTypeEfficient scroll closed
Quantity2222244
Supply air fanTypeLow noise centrifugal type
CapacitykW2.23445.57.57.5
EvaporatorTypeInner grooved copper tube and aluminum fin
Fin type 5*Slotted fin hydrophilic aluminum fin
CondenserTypeInner grooved copper tube and aluminum fin
Fin type 5*Rippled hydrophilic aluminum fin
Condenser fanTypeLow noise axial type
Quantity2224444
RefrigerantRefrigerantR22/R407C
Refrigerant controlExternal balance type thermal expansion valve
Air filterInitially effect plate filter
DimensionsLmm2200260026003200320060006000
Wmm1800220022002200220023002300
Hmm1520170017001900190023002300
Weightkg850110012501400165018502200

Note:
1. Cooling condition: Indoor dry bulb/wet bulb:29/19ºC,Outdoor dry bulb/wet bulb:46/24ºC
2. Heating condition:Indoor dry bulb/wet bulb:20/-ºC;outdoor dry bulb/wet bulb:7/6ºC;
3. The air volume and static pressure`s specification in the table is standard, and can be designable.
4. Noise data is measured in the front of the units when cooling under the standard air volume.
5. Fin type and material can be designable. 


Natural Gas Heating Coil Rooftop Air Handling Unit
Natural Gas Heating Coil Rooftop Air Handling Unit
Natural Gas Heating Coil Rooftop Air Handling Unit
Natural Gas Heating Coil Rooftop Air Handling Unit
Natural Gas Heating Coil Rooftop Air Handling UnitNatural Gas Heating Coil Rooftop Air Handling Unit

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours