Three-phase closed-loop electric energy meter test bench with Ict

    1.Features1.1 The bench accords with the standard of "IEC 60736:1982 Testing equipment for electrical energy meters", "IEC 62053"1.2 Close-link and ordinary calibration both&nb

Featured Products

 
  

Three Phase Close-Link Electrical Energy Meter Test Bench with Ict
 Three Phase Close-Link Electrical Energy Meter Test Bench with Ict

Three Phase Close-Link Electrical Energy Meter Test Bench with Ict

1.Features

1.1 The bench accords with the standard of "IEC 60736:1982 
Testing equipment for electrical energy meters", "IEC 62053"

1.2 Close-link and ordinary calibration both can be used, ordinary
calibration can be used to test single/three phase active and 
reactive energy meter(up to 0.5 class),close-link calibration can be 
used to test single/three phase active and reactive energy meter(up 
to 1 class).
 
 
1.3The bench can test the converted quantity which is caused by 
negative phase, voltage unbalance, harmonic wave and so on.

1.4 The bench can auto-calibrate starting, no load, basic error and
calibration tolerance and 24h deflection.

1.5 Close-link calibration is using insulate current transformer and
suitable for close-link energy meter.
1.6 The bench is using the error processor system to calculate the 
error of each energy meter by the sub-error system which can be 
connected by the internal RS485.

1.7 The same specification but different constant energy meter can 
be tested at one time.

1.8For the installed pick-up equipment, can offer 3 ranges 
adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.

1.9 The bench can choose to operate by keyboard or PC which is
convenient. The working status of bench can be seen very clear 
and easy operation.

1.10 The bench is using the testing software complied with
WINDOWS98/2000/XP which can auto-testing different energy 
meters. 

1.11 The software can realize the data from energy meter for 
statistics, search and management. It also can connect with on-line 
management for up load the data.

1.12 The energy meter hanging rack is made by Aluminum 
compound.The whole device configuration is a reasonable design 
and nice outfit.


2. Specification

2.1 Accuracy class: 0.05/0.1 class

2.2 Reference standard meter: 
HC3100H  Accuracy class: 0.02
HC 3100A  Accuracy class: 0.05/0.1

2.3  Isolated current transformer equipment:  
PTC-9503B insulate current inductance
Accuracy class:0.1(COSφ=0.5C-1-0.5L,0.1-100A) (200A optional)
Output power:30VA(MAX,100A)

2.4 Voltage amplifier:
Output voltage range: 30-400V (phase-neutral)
                                50-600V (phase-phase)
             Output power: 15VA(every meter)
Resolution: 0.01%
Stability: better than 0.05%/180s 
Distortion factor: < 0.5% at linear load
Frequency range: 45Hz~65Hz
Power efficiency: more than 85%
Ambient temperature:10ºC~50ºC

 2.5 Current amplifier:
Output current: range: 1mA~100A (200A optional)
Output  power: 40VA(every meter)
Resolution: 0.01%
Stability: better than 0.05%/180s 
Distortion factor: < 0.5% at linear load;
Frequency range: 45Hz~65Hz;
Power efficiency: greater than 85%;
Ambient temperature:10ºC~50ºC

2.6 Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;
2.7 Output frequency range: 45Hz~65Hz; resolution: 0.01Hz

2.8 Harmonic wave output:
      2-21 sub-harmonic wave contents=40%
      3,5,7 sub-harmonic wave couping, total content=40%
           Phase angel control (odd sub-harmonic wave)
           Wave group control (sub-harmonic wave)

2.9 Output stability of power: <0.05% (180s)

2.10 Numbers of calibrated energy meter: 16

2.11Input power: AC3x220/380V(Y) 15%, 50/60Hz


3. Other details
Three Phase Close-Link Electrical Energy Meter Test Bench with Ict

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours