Three-phase closed-loop electric energy meter test bench

Product Description1.Features1.1 The bench accords with the standard of "IEC 60736:1982 testing equipment for electrical energy meters", "IEC 62053"1.2 Close-link and ordinary calibration both can&nbs

Featured Products

Product Description

1.Features
1.1 The bench accords with the standard of "IEC 60736:1982 testing equipment for electrical energy meters", "IEC 62053"
1.2 Close-link and ordinary calibration both can be used, ordinary calibration can be used to test single/three phase active and reactive
energy meter(up to 0.5 class),close-link calibration can be used to test single/three phase active and reactive energy meter(up to 1 class).
1.3 The bench can test the converted quantity which is caused by negative phase, voltage unbalance, harmonic wave and so on.
1.4 The bench can auto-calibrate starting, no load, basic error and calibration tolerance and 24h deflection.
1.5 Close-link calibration is using insulate current transformer and suitable for close-link energy meter.
1.6 The bench is using the error processor system to calculate the error of each energy meter by the sub- error system which can be connected by the internal RS485.
1.7 The same specification but different constant energy meter can be tested at one time.
1.8 For the installed pick-up equipment, can offer 3 ranges adjustment. It is also can be accepted the signal for both round-style energy meter and digital LED energy meter.
1.9 The bench can choose to operate by keyboard or PC which is convenient.  The working status of bench can be seen very clear and easy operation.
1.10 The bench is using the testing software complied with WINDOWS98/2000/XP which can auto-testing different energy meters. 
1.11 The software can realize the data from energy meter for statistics, search and management. It also can connect with on-line management for up load the data.
1.12 The energy meter hanging rack is made by Aluminum compound.The whole device configuration is a reasonable design and nice outfit.

Product Parameters

2. Specification
2.1 accuracy class: 0.1 class (close-link calibration, the range of current: 0.1A-100A) (200A optional)
                                 0.05/0.1 class (open-link calibration)
2.2 standard power testing equipment
                                 HC 3100H   Accuracy class: 0.02 class
2.3  Isolated current transformer equipment:  
                                 PTC-9503B insulate current inductance
                                 Accuracy class:0.1(COSφ=0.5C-1-0.5L,0.1-100A) (200A optional)
                                 Output power:30VA(MAX,100A)
2.4 Voltage amplifier:
                                 Output voltage range: 30-400V (phase-neutral)
                                 50-600V (phase-phase)
                                 Output maximum power: 800VA (every meter)
                                 Resolution: 0.01%;
                                 Stability: better than 0.05%/180s (time base 5s);
                                 Distortion factor: < 0.5% at linear load;
                                 Frequency range: 45Hz~65Hz;
                                 Power efficiency: more than 85%;
                                 Ambient temperature:10ºC~50ºC
                                 Electronic overload and short-circuit protection.
2.5 Current amplifier:
                                Output current: range: 1mA~100A (200A optional)
                                Output maximum power: 1500VA
                                Resolution: 0.01%;
                                Stability: better than 0.05%/180s (time base 5s);
                                Distortion factor: < 0.5% at linear load;
                                Frequency range: 45Hz~65Hz;
                                Power efficiency: greater than 85%;
                                Ambient temperature:10ºC~50ºC
                                Electronic overload protection and security for open current circuit.
2.6 Phase Angle: 0°~360° , resolution of phase angle setting: 0.1°;
2.7 Output frequency range: 45Hz~65Hz; resolution: 0.01Hz
2.8 Harmonic wave output:
2-21 sub-harmonic wave contents=40%
         3,5,7 sub-harmonic wave couping, total content=40%
         Phase angel control (odd sub-harmonic wave)
         Wave group control (sub-harmonic wave)
2.9 Output stability of power: <0.05% (180s)
2.10 Numbers of calibrated energy meter: 8-20
2.11Input power: 3x220/380V(Y) 15%, 50/60Hz; Max. power consumption: 6000VA 

Detailed Photos

Three Phase Close-Link Energy Meter Test BenchThree Phase Close-Link Energy Meter Test Bench
Three Phase Close-Link Energy Meter Test Bench

Company Profile

 

3. Other details
Three Phase Close-Link Energy Meter Test Bench

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours